Dominion Energy, Inc. earnings recap
Q3 FY2026, reported October 30, 2026 · Beat 7 of last 7 quarters
Dominion Energy, Inc. reported Q3 FY2026 revenue of $5.62B, a beat of 14.6% against consensus, and EPS of $1.28, a beat of 5.8%.
The Buildout is a website built by one person using AI agents, and could have factual errors.
Dominion's quarter is a direct read on AI-driven load: 54 GW of data center capacity in contracting, including 12 GW signed, is demand that ultimately has to be served by new generation, transmission and storage that does not yet exist. The IRP update — 4 GW of accelerated solar and 2 GW of battery storage, with battery capacity up roughly 4x by 2034 — plus $2.5 billion to $3 billion per gigawatt of capital suggests the constraint has shifted from demand to build execution and regulatory recovery. CVOW's 85% completion and unchanged cost and schedule, alongside a pending NextEra combination, are the two variables that determine how much of that build Dominion can finance and construct on schedule.
| Estimate | Actual | vs est | ||
|---|---|---|---|---|
| Revenue | $4.90B | $5.62B | +14.6% | beat |
| EPS | $1.21 | $1.28 | +5.8% | beat |
Third-quarter operating earnings were $1.28 per share versus $1.30 on a GAAP basis, with $0.05 each from RNG 45Z credits and better-than-normal weather. Load growth remained the headline: LTM weather-normal electric sales rose 3.4% across the two electric utilities, all 10 of the DOM Zones top summer peak days fell in 2026, and DESC set an all-time peak in August. The data center pipeline grew to more than 54 GW in various stages of contracting, including over 12 GW under electric service agreements — an increase of more than 6 GW, or 13%, since the end of last year — brought on under the SCC-approved large load framework. CVOW reached roughly 85% complete with 44 turbines installed and all major component fabrication finished, though September and October installation ran below plan on weather and Charybdis maintenance that management said fell within the contingency added last quarter. Elsewhere, the Virginia SCC approved roughly $900 million of fuel securitization in September, a mid-October IRP update accelerated solar and storage additions, and Millstone's existing PPA is expected to save Connecticut customers over $245 million this year and more than $900 million over its ten-year life.
Management lifted the full-year outlook to the top half of the original operating EPS guidance range, citing better-than-budgeted sales, better-than-normal weather and higher 45Z credit income, while explicitly reserving conservatism for November-December weather and for actions that could derisk future years. All other guidance was reaffirmed, including credit, dividend and long-term growth, and the CFO characterized 2027 and 2028 as relatively lighter equity years within the five-year financing plan. On CVOW, the $11.65 billion budget (including $123 million of unused contingency) and end-2027 completion date are unchanged despite a slower September-October installation cadence, with the third and final offshore substation targeted for energization by year-end 2026 and an LCOE still below the statutory threshold. The October Virginia IRP update adds and accelerates 4 GW of solar and 2 GW of battery storage, with management sizing each incremental gigawatt at roughly $2.5 billion to $3 billion of opportunity on a two-year spend cycle ahead of commercial operation. The NextEra combination remains on the same calendar — rebuttal testimony November 2, Virginia hearings beginning November 17 with a final order due by January 11, 2027, and South Carolina hearings December 8 with a final order by January 29, 2027 — with closing still expected in the second half of 2027. Management also said it expects a clearer read on the Connecticut zero-carbon solicitation, and therefore Millstone's path, by the end of the year.
“We now have over 54 gigawatts of data center capacity in various stages of contracting, including over 12 gigawatts of capacity contracted under electric service agreements.”
on Data center pipeline
“Inclusive of conservatism for balance of year weather, as well as potential opportunities to derisk future financial performance, we now expect full year results to be in the top half of our original guidance range.”
on Full-year guidance
“Relative to last year's company preferred plan, we have added and accelerated 4 gigawatts of solar and 2 gigawatts of battery storage.”
on Virginia IRP update
On the merger and the 57 conditions in staff testimony — where are you and the staff furthest apart, what is the deal breaker (ring fencing, dividend restriction), can you close gaps before next month's hearings, and how is the dialogue with the governor's intervention going?
Blue said a chunk of the 57 conditions were ones Dominion had already voluntarily proposed, and that the case will be decided on the statutory no-harm standard, which management believes it exceeds by offering affirmative customer, employee and community benefits. Rebuttal testimony was to be filed the following Monday ahead of hearings starting November 17. On the governor, he said she is participating as an intervener, that her intervention was welcomed, and that the company's focus is the testimony filing and the no-harm legal standard.
Beyond jack-up to jack-down time tracking in line with expectations, what other items can impact CVOW's overall timing and how should we expect them to trend over the next few months, particularly weather?
Blue listed weather, maintenance, transit and load-out time as the swing factors, noting load-out times continue to improve and transit is being sequenced to avoid criss-crossing the lease area, and that installation has gotten 35% to 45% faster from the first ten turbines to the most recent nine. Ridge quantified it: of the last ~91 days, 14 were weather-impacted and ~36 hit by vessel maintenance, leaving ~41 available days for 13 turbines, or about 3.2 calendar days each — and about 425 calendar days remain to install 132 turbines, coincidentally also 3.2 days apiece. At 1.5 days per jack-up/jack-down the remaining installation takes roughly 200 days, at 2 days about 265, plus ~130 days for roughly 33 port load-outs, leaving 30 to 95 days of buffer.
On the new Virginia IRP with the 4 GW and 2 GW pull-forward, what could that do to the capital plan and rate base growth — any color you can provide?
Ridge said the update increases battery on the system roughly 4x through 2034 versus the 2025 IRP — 850 MW for 2020-2030 previously versus 3.3 GW now — with a roughly two-year capital cycle ahead of commercial operation. As 2031 rolls into the five-year plan, the company picks up an additional year of the enhanced battery opportunity, which management frames at $2.5 billion to $3 billion per gigawatt. Some of the IRP would be under a PPA structure and excluded from rate base, but the majority is self-build consistent with the Virginia Clean Economy Act, which he called a meaningful capital opportunity.